- Standard Acoustic Enclosures (Heat Pumps, Pool Heat Pumps, Aricon-, VRF/VRV units - Single Fan and Double Fan units)
- >
- Silent H-3 Acoustic Enclosure for Heat Pumps / Air Conditioning Systems / Mini VRV/VRF units
Silent H-3 Acoustic Enclosure for Heat Pumps / Air Conditioning Systems / Mini VRV/VRF units
Acoustic Enclosure for heat pumps / air conditioning systems / Mini VRV/VRF systems with horizontal air flow.
Sound reduction down to 18 -21 dB(A) through targeted air flow in combination with insulation to prevent masking effects and reflected sound.
Sound hoods standard model for systems with 1 axial fan and a maximum air volume of 4'850 m3 / h (= systems with 11 to 16 kW)
Service doors around the systems / "plenum sheets" to prevent an air short circuit. Depending on the situation, the air inlet and air inlet openings can be placed around the system, which means that several systems can be set up in a row (cascade) without creating an air short circuit.
Material Aluminum system profiles with a thickness of 5 cm, aluminum panels with powder coating in RAL color of your choice, with a thickness of 1.5 mm with internal weather-resistant insulation with a thickness of 40 mm.
Sound insulation in the inside of the service doors is equipped with sound insulation based on sound-absorbing polyethylene foam sheets with a thickness of 40 mm.
Due to its sound-absorbing properties, this foam is one of the most innovative materials for sound control in industry. The material is water, UV and dimensionaly stable and does not build up bacteria (fungi) and is completely recyclable.
Thanks to the numerous certifications, the panels can be used in the following areas: construction, industry, rail vehicles, automotive, electronics, shipping, ducting and air conditioning. «FR version» of this sound insulation is flame retardant.
Size of the acoustic hood
External dimensions: 1'800 x 1'250 x 1'600 mm (L x B x H)
Internal dimensions: 1'700 x 1'150 x 1'500 mm (L x B x H) mm
Maximum system size
External dimensions: 1'100 x 460 x 1'400 mm (L x W x H)
Air Volume
Maximum air volume Heat pumps: 7'800 m3/h
Air conditioning systems: 6'900 m3/h
VRF / VRV systems: 6'900 m3/h
Pressure loss through the acoustic hood approx. 13 Pascal
Color at your choice within the entire RAL color palette at no extra charge.