Sound insulation from small systems to system groups..

HVAC-Noise pollution

Noise pollution has been well documented to engender a variety of physical and psychological problems. Workers face heightened risk for everything from elevated blood pressure, hearing loss, and heart attack to increased vulnerability to various neuropsychiatric disorders. While many of these problems are cumulative resulting from long term exposure, short-term effects include reduced productivity and impaired communications.

The general rule-of-thumb is that noise is excessive when people can no longer speak in normal conversational tones from a distance of six feet or two meters. In mission-critical environments or in an emergency, this can be life threatening.
​
Background noise, such as that emitted from HVAC and Industrial systems, has unfortunately, become the soundtrack for day-to-day life in both work and home environments.

This no longer has to be the case. - Our enclosures cancels out noise while generating a variety of other benefits, including improved HVAC functioning and reduced energy consumption.​
Picture

Enclosures acoustic principals

Our Acoustic Enclosure’s are simple device, incorporating clever acoustic principals to achieve the optimal noise attenuation.
Our Enclosures work on three principals;

- Sound insulation,
- Sound absorption
- Incident sound wave noise cancellation.


All of which contribute to high noise performance characteristics.
​
Not only this, our enclosure design provides a unique process to enable air to move freely in and out of our Enclosure Systems without compromising equipment efficiencies - thus optimising air flow volume and most importantly ensuring no recirculation occurs.

All of our acoustic dampening products offer unique and cost effective solution to control excessive noise, protect against vandalism and reduce equipment degeneration. All packaged in an unobtrusive and attractive design.
Picture

Acoustic enclosures features

Noise reduction up to 25 dB(A) over the entire frequency spectrum 63 Hz to 8,000 Hz.

Choice of different airflow principles.

Modularly adaptable to any system size by using standard modules.

Free Access to the equipment for Maintenance and Service trough service doors around the Equipment.

Easy and fast installation for retrofitting existing equipment or new installations.

Choice of different RAL colors or graphic patterns (optional) to adapt the enclosure to the environment.

Cost-effective solution for the construction HVAC systems in acoustically problematic areas.

Design of the acoustics enclosures to the required air volume (pressure loss <20 Pascal).

Protection of the systems against environmental influences (rain, snow, hail, dust, sand) and unauthorized access.

Screen protection of the Equipment.

Made of aluminium including UV, weather, fungus- and fire resistant insulation.

All components are recyclable.

Light construction, construction also possible on foil roofs with corresponding wind load protection.

Picture
Acoustic enclosures for HVAC Equipment

How we work

​Decisive for the performance of HVAC systems is the air flow, for this reason, the air openings (air inlet / outlet) are dimensioned due to the Manufacturer specifications.
In this way, we achieve optimum performance of the systems, with whisper-quiet operation and a pressure drop of <20 Pascal across the various types of systems. We offer everything from the complete design to the service from a single source.

If you plan an offer for specific applications, the easiest way is to follow the steps below:.

Step 1
Send us information about the manufacturer, brand and model (exact name) of the equipment for which a enclosure is to be used. Further information on the location of the system and any existing acoustic report are helpful, but are not needed in a first phase. Send us the information via e-mail or let us know by phone.

Step 2
Acoustic enclosure specifications Based on the details of the system, we will calculate the enclosures dimension and provide you with detailed information. This information includes: Noise reduction data, air flow information, dimensions, sketch design, price and delivery times.

Step 3
Production and delivery If you agree with the offer and order the system we go into production.

Get in touch with us

Submit
Picture

Navigate Silent-Mode

Home
 
Products + Services

About us 

Impressum 

​Contact 
​
​Privacy 

Contact us 

Italy 


Silent Mode 
di Romolo Vicari
Via Trento 22 
IT-23875 Osnago 

Warehouse: 
Via Milano, 41, 23899 Robbiate LC, 

info@silent-mode.com 
Tel. +39 349 431 73 42 

Slovenia 

Ogrevanje Škrbec d.o.o.
​
Dol pri Borovnici 42
1353 BOROVNICA
Tel. + 386 408 585 92

E-Mail: andrej.skrbec@gmail.com
​Webseite: Slovenia 

Contact: Andrej Skrbec​ 

Switzerland

Systemregeltechnik GmbH 
Steinhofweg 4 
CH-8112 Otelfingen 

suisse@silent-mode.com 
Tel. +41 79 872 06 66 

​UK

Clever Engineering (Kent) Ltd Unit B2, 
St. George's Business Park, Castle Rd, Sittingbourne ME10 3TB
.

technical.sales@cleverengineering.co.uk 

Contact: Trevor Carter


German Website 

www.silent-mode.com 


​
Website Content

Environment Acoustic Enclosures for new systems and retrofitting of existing heat pumps, air conditioning, refrigeration systems, compressors, battery charging stations etc.

©Copyright 2017/2018/2019/2020
All contents, especially texts, images are protected by copyright. All rights, including reproduction, publication, editing and translation, are reserved.

Owner
Silent-Mode di Romolo Vicari , Via Trento 22, 23875 Osnago
info@silent-mode.com

  • Home
  • Products
  • About us
  • Blog
  • Contact
  • Deutsch